Hp Array Controller HSG V8.7 Software Manuel d'utilisateur Page 407

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 576
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 406
CLI Commands B135
REPLACE=disk-name
Instructs the controller to add a disk member to an existing RAIDset if
the following conditions are met:
The replacement policy is set to NOPOLICY.
The disk member is not in any configuration, including a spareset.
An error is displayed and the command is rejected if the RAIDset is not
in a reduced state, if a replacement policy is already specified, or if the
disk specified is already being used by a configuration (including a
spareset).
Note Do not specify other switches when you use the REPLACE=
switch.
Examples
This example shows how to change the replacement policy for RAIDset
RAID9 to BEST_FIT:
SET RAID9 POLICY=BEST_FIT
This example shows how to remove member DISK10000 from the
RAID9 RAIDset:
SET RAID9 REMOVE=DISK10000
If there is a replacement policy, the controller moves a disk from the
spareset to the RAIDset automatically.
This example shows how to add disk DISK20100 to the reduced
RAIDset, RAID9:
SET RAID9 REPLACE=DISK20100
Reconstruction immediately begins on DISK20100.
See also
ADD RAIDSET
SHOW RAIDSETS
Vue de la page 406
1 2 ... 402 403 404 405 406 407 408 409 410 411 412 ... 575 576

Commentaires sur ces manuels

Pas de commentaire