24 HSG80 Users Guide
If this is a single configuration with a single hub, set PORT 2 off-line.
If this is a dual-redundant configuration, the other controller inherits
this controllers port topology.
See Appendix B, CLI Commands, for more information about using
the SET THIS_CONTROLLER PORT_n_TOPOLOGY= command.
8. If you selected LOOP_HARD for the port topology, specify the
arbitrated loop physical address (ALPA) for the host ports.
SET THIS_CONTROLLER PORT_1_ALPA=address
SET THIS_CONTROLLER PORT_2_ALPA=address
If this is a dual-redundant configuration, the other controller inherits
this controllers port ALPA addresses.
See Appendix B, CLI Commands, for more information about using
the SET OTHER_CONTROLLER PORT_n_ALPA= command.
9. Put this controller into transparent failover mode. Use the following
syntax:
SET FAILOVER COPY = THIS_CONTROLLER
The other controller inherits this controllers configuration, then
restarts. Wait for it to return to normal operation before continuing.
See details about failover modes in Selecting a Failover Mode, page
210.
10. Put this controller in multiple-bus failover mode using the follwing
syntax:
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
The other controller inherits this controllers configuration, then
restarts. Wait for it to return to normal operation before continuing.
See Selecting a Failover Mode, page 210, for details about failover
modes.
11. Optional: Change the CLI prompt. Type the following command:
SET THIS_CONTROLLER PROMPT = new prompt