Event Reporting: Templates and Codes D–27
0311430A
Nonvolatile memory and drive metadata indicate conflicting drive
configurations.
51
0312430A
The Synchronous Transfer Value differs between drives in the same
storageset.
51
03134002 Maximum number of errors for this data transfer operation exceeded. 51
03144002 Drive reported recovered error without transferring all data. 51
03154002 Data returned from drive is invalid. 51
03164002 Request Sense command to drive failed. 51
03170064 Illegal command for pass through mode. 51
03180064 Data transfer request error. 51
03194002 Premature completion of a drive command. 51
031A4002 Command timeout. 51
031B0101 Watchdog timer timeout. 51
031C4002 Disconnect timeout. 51
031D4002 Unexpected bus phase. 51
031E4002 Disconnect expected. 51
031F4002 ID Message not sent by drive. 51
03204002 Synchronous negotiation error. 51
03214002 The drive unexpectedly disconnected from the SCSI bus. 51
03224002 Unexpected message. 51
03234002 Unexpected Tag message. 51
03244002 Channel busy. 51
03254002 Message Reject received on a valid message. 51
0326450A The disk device reported Vendor Unique SCSI Sense Data. 51
03270101
A disk related error code was reported which was unknown to the Fault
Management firmware. Note that in this instance the Associated
Additional Sense Code and Associated Additional Sense Code Qualifier
fields are undefined.
41
0328450A The disk device reported standard SCSI Sense Data. 51
03324002 SCSI bus selection timeout. Pass-through
03330002 Device power on reset. Pass-through
03344002 Target assertion of REQ after WAIT DISCONNECT. Pass-through
03354002
During device initialization a Test Unit Ready command or a Read
Capacity command to the device failed.
Pass-through
03364002 During device initialization the device reported a deferred error. Pass-through
Table D–1 Instance Codes (Continued)
Instance
Code
Description Template