Hp Array Controller HSG V8.7 Software Manuel d'utilisateur Page 152

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 576
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 151
374 HSG80 Users Guide
9. Represent the storageset to the host by giving it a unit number the host
can recognize. You can use the original unit number or create a new one.
Use the following command:
ADD UNIT unit-number storageset-name
Example
The following example moves unit D100 to another cabinet. D100 is
the RAIDset RAID99 that is comprised of members DISK10000,
DISK20000, and DISK30000.
SHOW RAID99
DELETE D100
DELETE RAID99
DELETE DISK10000
DELETE DISK20000
DELETE DISK30000
(...move the disk drives to their new location...)
ADD DISK DISK20000 2 0 0
ADD DISK DISK30000 3 0 0
ADD DISK DISK40000 4 0 0
ADD RAIDSET RAID99 DISK20000 DISK30000 DISK40000
ADD UNIT D100 RAID99
Name Storageset Uses Used by
RAID99 raidset disk10000
disk20000
disk30000
D100
Vue de la page 151
1 2 ... 147 148 149 150 151 152 153 154 155 156 157 ... 575 576

Commentaires sur ces manuels

Pas de commentaire