
B–84 HSG80 User’s Guide
Table B–3 shows what action will be taken depending on the switch
settings and the results of the attempted flush:
Table B–3 POWEROFF Switch Settings
In dual-redundant mode, if both controllers can’t be shutdown, then
both controllers and their batteries’ chargers remain on.
Example
This example shows how to power off the disk units and the cabinet in
10 seconds (BATTERY_OFF and NO_OVERRIDE_BAD_FLUSH are
the defaults):
POWEROFF SECONDS=10
Battery Switch Override Switch
Flush
Results
Action
BATTERY_ON OVERRIDE_BAD_FLUSH Success
Controller and units in cabinet
shutdown, ECB charger remains on.
BATTERY_ON OVERRIDE_BAD_FLUSH Failure
Controller and units in cabinet
shutdown, ECB charger remains on.
BATTERY_ON NO_OVERRIDE_BAD_FLUSH Success
Controller and units in cabinet
shutdown, ECB charger remains on.
BATTERY_ON NO_OVERRIDE_BAD_FLUSH Failure
Nothing is shutdown, ECB charger
remains on, user is notified of a bad
flush.
BATTERY_OFF OVERRIDE_BAD_FLUSH Success
Controller and units in cabinet
shutdown, ECB charger turned off.
BATTERY_OFF OVERRIDE_BAD_FLUSH Failure
Controller and units in cabinet
shutdown, ECB charger turned off.
BATTERY_OFF NO_OVERRIDE_BAD_FLUSH Success
Controller and units in cabinet
shutdown, ECB charger turned off.
BATTERY_OFF NO_OVERRIDE_BAD_FLUSH Failure
Nothing is shutdown, ECB charger
remains on, user is notified of a bad
flush.
Commentaires sur ces manuels